Primary focus · AI data centers

Energy control for the AI load.

High power density, fast load changes, the need for continuity and pressure on grid capacity meet in the same facility. Data centers are our primary focus.

AI data center
Schematic
123
  1. SenseCoreUPS batteryCell-level measurement and pack control.
  2. SiteFacility control layerCoordinates grid, generator and battery as one system.
  3. BBUGPU server racksBackup power in every rack, closest to the load.
Where Wattality products sitCutaway view · not to scale

The need

An AI load behaves unlike a classic data-center load.

  1. 01

    Load changes in milliseconds

    The load ramps as a job starts, overshoots at the peak, falls idle and oscillates while running. Storage covers the difference and leaves the grid a smooth profile.

  2. 02

    Access to power

    How fast new capacity arrives depends on the availability and flexibility of the power that feeds it. Storage and control help make better use of the existing connection.

  3. 03

    Control that stays on site

    Operators want control that runs inside the site, does not depend on the cloud and follows their own security rules.

Our approach

We meet the load swing across different time scales.

We are designing the BBU to absorb millisecond surges closest to the server rack and the facility battery to cover longer swings. Site decides which source acts when; Sense and Core bring the battery's real capacity at that moment into the decision.

AI load and the envelope asked of the grid
Schematic
RampPeakIdleOscillationShutdown
AI loadEnvelope asked of the gridStorage covers the difference

Power distribution

From the grid to the server rack, one chain.

Power reaches the server racks from the grid or a generator, through medium-voltage distribution and the uninterruptible power supply. The battery carries the load while the source changes; the BBU does the same job closest to the server. We are developing Site to coordinate the sources in this chain as one system.

We design the power distribution architecture and redundancy structure for AI data centers and critical facilities.

Power distribution in a data center
Schematic

UPS type

SiteGrid● FeedingGenerator○ StandbyMV switchgearMV UPSRectifierInverterDC linkBattery○ StandbySense · CoreMV/LV transformerLV panelBBUServer rack○ Standby

The grid feeds the load through the MV UPS. The battery stays charged on the UPS DC link; the BBU stands by inside the rack.

Where Wattality products sit

Site
Designed to coordinate grid, generator and battery as one system, from outside the protection chain. Trips and interlocks stay hardwired.
Sense · Core
Cell-level measurement and pack control for the UPS battery.
BBU
Backup power on the rack's own power line.
Power flowDe-energizedControl and measurement

Let's talk about your facility.

Write to us about your application and our technology.